Sample 0363
Detected

Surface inspection
Compare photographs of six types of film defect with the corresponding CRD segmentation heatmaps.
Both views show the same area of film. Pale yellow indicates a stronger model response and dark purple a weaker one.


These 18 image pairs come from the held-out defect set. Select a defect type to compare each photograph with its model output.




































The test images were held apart from training and validation. At the selected alarm threshold, 97.54% of the defect photographs triggered an alert. Assessing the production false-alarm rate still requires photographs of defect-free film.